Ensure wall insulation is installed at least 225 mm below top of floor insulation.
Ground floor insulation detail.
Insulating solid ground floors above ground bearing slab sand blinding and hardcore concrete slab dpm quinn therm qf pir insulation boards quinn lite pac eps insulation boards quinn therm edge insulation screed with u f heating pipes on separating layer timber flooring on polyethylene slip sheet sand blinding and hardware concrete slab.
Insulating a solid ground floor below the ground bearing concrete slab can be done using either pir insulation boards or eps insulation boards.
You should seek the advice of a structural engineer regarding the suitability of any insulation product in a specific floor system.
Seal all penetrations through air barrier using a flexible sealant.
1 upgrading an existing slab the simplest way of improving the thermal performance of an existing concrete ground floor is to add insulation and a new floor deck on top of the existing floor.
For the floors of industrial.
Ground floor insulation above slab plus lightweight block.
Ground floor insulation methods.
The building detail is for illustrative.
Jabfloor 250 will stand up to the loads in a cold store and should be laid in two layers of 100mm with boards cross laid to reduce the risk of any cold bridging.
It helps make effective use of the thermal mass of the concrete slab rather than repeatedly warming it and allowing it to cool.
Ground floor insulation below concrete slab thermal insulation is usually installed below the floor slab in buildings featuring continuous low level heating.
Concrete floor the choice of insulation position relative to the concrete slab is commonly linked to the building s heating system.
Though simple raising the floor level through added insulation will usually require skirtings and radiators to.